I've just changed the motor on my central heating diverter valve but do not get any current flow in one of connections to the motor. The other connection is fine. Should there be current in both connections to the motor?

Brendan
Old 22 December 2002, 06:50 PM
  #2  
tezza
Scooby Regular
 
tezza's Avatar
 
Join Date: Dec 2001
Posts: 177
Likes: 0
Received 0 Likes on 0 Posts
Post

I take it that it now works?
With any motor on vavle it should be power in (240v) moves/does something uses power up none out(ie is neutral side of motor) Layman terms obviously.
So in answer to question it should be ok.
terry
Old 22 December 2002, 09:43 PM
  #3  
BHORT
Scooby Regular
Thread Starter
 
BHORT's Avatar
 
Join Date: Apr 1999
Posts: 271
Likes: 0
Received 0 Likes on 0 Posts
Post

I'm still getting hot radiators when only the hot water is on. I think that it may be the cogs on the motor not meshing with those on the valve, or the valve is stuck. Is there any way operate the valve manually i.e one position for heating and one for hot water?

Brendan
Old 23 December 2002, 07:03 PM
  #4  
scooby nutter
Scooby Regular
 
scooby nutter's Avatar
 
Join Date: Dec 2000
Posts: 1,028
Likes: 0
Received 0 Likes on 0 Posts
Post

Slide the lever straight across and wedge it in the groove.
this will bring the rads+hw on,if its a y plan system i think the rads will only stay on until the HW is upto temp,they will switch off after that.

Sounds like the valve is knakerd,if you changed the motor and its still playing up you need a replacement,the ***** sometimes fall off,or the microswitches blow
Also had a problem the other week where the heating wouldnt work on its own.turns out to be the roomstat that someone had taken off and wired it back up incorrectly!!
Old 23 December 2002, 07:32 PM
  #5  
tezza
Scooby Regular
 
tezza's Avatar
 
Join Date: Dec 2001
Posts: 177
Likes: 0
Received 0 Likes on 0 Posts
Post

Sounds like the valve as scooby nutter said is in need of changing. If the heating is on when only the hot water is calling for(on) then the valve maybe letting-by(most likely), the room stat is faulty, programmer faulty or the valve is stuck in the manaul position(check lever is not in catch) so allowing water into the heating circuit.
terry
Old 23 December 2002, 07:39 PM
  #6  
Mog
Scooby Regular
 
Mog's Avatar
 
Join Date: May 2001
Location: Suffolk, very near Adnams !!
Posts: 2,860
Likes: 0
Received 0 Likes on 0 Posts
Post

Has the problem just started or have you inheirited it (new house)
as it could be something else....

Mog
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
JimBowen
ICE
5
02 July 2023 01:54 PM
SilverM3
ScoobyNet General
8
24 February 2021 01:03 PM
shorty87
Full Cars Breaking For Spares
19
22 December 2015 11:59 AM
alex_00s
Drivetrain
2
26 September 2015 06:07 PM
shorty87
Other Marques
0
25 September 2015 08:52 PM



Quick Reply: changing motor on diverter valve



All times are GMT +1. The time now is 01:10 PM.