Default Electrical socket help....

I have replaced pretty much every socket in the house with these.....




The only socket left visible is this one which is for the water pump in the bathroom.




Obviously due to the electrical regs, I can't just swap it for a fused spur which are easily available in the black nickel colour so I want to find one of these which is a least in keeping with the rest of the house. This be my problem. I can't for the life of me find anything which comes close. Any thoughts?
Old 04 July 2016, 03:27 PM
  #2  
JDM_Stig
Scooby Regular
iTrader: (3)
 
JDM_Stig's Avatar
 
Join Date: Feb 2009
Location: Mount Weather
Posts: 5,840
Received 41 Likes on 33 Posts
Default

is there a RCD on the circuit that feeds this pump spur ?
Old 04 July 2016, 03:51 PM
  #3  
cookstar
Scooby Regular
iTrader: (6)
 
cookstar's Avatar
 
Join Date: Apr 2005
Location: Stroke it baby!
Posts: 33,828
Likes: 0
Received 0 Likes on 0 Posts
Default

http://www.screwfix.com/p/13a-30ma-d...ion-unit/40097

Any good?
Old 04 July 2016, 03:55 PM
  #4  
hodgy0_2
Scooby Regular
 
hodgy0_2's Avatar
 
Join Date: Jul 2008
Location: K
Posts: 15,633
Received 21 Likes on 18 Posts
Default

they do version of those sockets with inbuilt USB ports - pretty handy
Old 04 July 2016, 04:18 PM
  #5  
royals8088
Scooby Newbie
 
royals8088's Avatar
 
Join Date: Jun 2016
Location: west mids
Posts: 3
Likes: 0
Received 0 Likes on 0 Posts
Default

You must check the bonding on every socket. The new socket faces are now metal? If so you must bond from the socket to the back box if that is also metal. 1.5mm2 is all that is required from socket to box, 2.5mm2 is the norm
Old 04 July 2016, 07:13 PM
  #6  
Brun
Scooby Senior
Thread Starter
 
Brun's Avatar
 
Join Date: Apr 2002
Location: Harrogate
Posts: 14,229
Likes: 0
Received 5 Likes on 5 Posts
Default

Originally Posted by hodgy0_2
they do version of those sockets with inbuilt USB ports - pretty handy
I have a few
Old 04 July 2016, 07:14 PM
  #7  
Brun
Scooby Senior
Thread Starter
 
Brun's Avatar
 
Join Date: Apr 2002
Location: Harrogate
Posts: 14,229
Likes: 0
Received 5 Likes on 5 Posts
Default

Originally Posted by cookstar
No - I want the black nickel look
Old 04 July 2016, 07:15 PM
  #8  
Brun
Scooby Senior
Thread Starter
 
Brun's Avatar
 
Join Date: Apr 2002
Location: Harrogate
Posts: 14,229
Likes: 0
Received 5 Likes on 5 Posts
Default

Originally Posted by royals8088
You must check the bonding on every socket. The new socket faces are now metal? If so you must bond from the socket to the back box if that is also metal. 1.5mm2 is all that is required from socket to box, 2.5mm2 is the norm
Bond????????
Old 04 July 2016, 07:20 PM
  #9  
Brun
Scooby Senior
Thread Starter
 
Brun's Avatar
 
Join Date: Apr 2002
Location: Harrogate
Posts: 14,229
Likes: 0
Received 5 Likes on 5 Posts
Default

Originally Posted by JDM_Stig
is there a RCD on the circuit that feeds this pump spur ?
I guess - this is the main fuse box for the house and the second from the right will turn the power off.

Old 04 July 2016, 07:24 PM
  #10  
JDM_Stig
Scooby Regular
iTrader: (3)
 
JDM_Stig's Avatar
 
Join Date: Feb 2009
Location: Mount Weather
Posts: 5,840
Received 41 Likes on 33 Posts
Default

You need a new consumer unit more than posh looking accessories!
Old 04 July 2016, 07:25 PM
  #11  
The Pink Ninja
Scooby Regular
iTrader: (23)
 
The Pink Ninja's Avatar
 
Join Date: Apr 2008
Location: ...
Posts: 6,703
Likes: 0
Received 2 Likes on 2 Posts
Default

Why is there no rcd for shower/cooker etc?
Old 04 July 2016, 07:27 PM
  #12  
johned
Scooby Regular
 
johned's Avatar
 
Join Date: Jan 2010
Location: derbyshire
Posts: 2,002
Likes: 0
Received 16 Likes on 12 Posts
Default

+1 above and sooner rather than later.
Old 04 July 2016, 08:08 PM
  #13  
b3nmw
Scooby Regular
 
b3nmw's Avatar
 
Join Date: Mar 2009
Location: sunny wales
Posts: 1,100
Likes: 0
Received 0 Likes on 0 Posts
Default

Is there an rcd else whether other than the consumer unit. I reckon u could die with a consumer unit change
Old 04 July 2016, 08:08 PM
  #14  
b3nmw
Scooby Regular
 
b3nmw's Avatar
 
Join Date: Mar 2009
Location: sunny wales
Posts: 1,100
Likes: 0
Received 0 Likes on 0 Posts
Default

Do not die( stupid predictive text)
Old 04 July 2016, 08:36 PM
  #15  
Brun
Scooby Senior
Thread Starter
 
Brun's Avatar
 
Join Date: Apr 2002
Location: Harrogate
Posts: 14,229
Likes: 0
Received 5 Likes on 5 Posts
Default

Originally Posted by The Pink Ninja
Why is there no rcd for shower/cooker etc?
No power shower

As for the cooker - none of these switch it off
The cooker is in the extension (built before we moved in) so there could be another consumer unit.

Just had a look behind the cooker and there is a big mother of a wire coming from it which disappears into the wall. Tomorrows mission will be to find the end of it
Old 04 July 2016, 08:37 PM
  #16  
JDM_Stig
Scooby Regular
iTrader: (3)
 
JDM_Stig's Avatar
 
Join Date: Feb 2009
Location: Mount Weather
Posts: 5,840
Received 41 Likes on 33 Posts
Default

take picture of where the meter is and any other consumer units you have in the extension.
Old 04 July 2016, 08:53 PM
  #17  
Osimabu
Scooby Regular
iTrader: (2)
 
Osimabu's Avatar
 
Join Date: May 2011
Location: .
Posts: 1,341
Likes: 0
Received 0 Likes on 0 Posts
Default

It might be worth contacting the manufacturers of your metallic sockets (not the suppliers) and seeing if they can help you.

But I suspect that your best bet is going to be to bring the wiring up to modern standards and you may find you don't need the fused spur with the trip any longer.

However, I am not an electrician.
Old 04 July 2016, 09:05 PM
  #18  
ALi-B
Moderator
Support Scoobynet!
iTrader: (1)
 
ALi-B's Avatar
 
Join Date: Apr 2002
Location: The hell where youth and laughter go
Posts: 38,034
Received 301 Likes on 240 Posts
Default

Originally Posted by Brun
Bond????????
After looking at the consumer unit, this is even more essential to have a earth wire on the socket face plates.

I know it sounds like we're being **** but that comsumer unit needs to go. The bright side means you can have the RCD or RCBO in the consumer unit so you can then fit a matching spur.
Old 04 July 2016, 09:21 PM
  #19  
Brun
Scooby Senior
Thread Starter
 
Brun's Avatar
 
Join Date: Apr 2002
Location: Harrogate
Posts: 14,229
Likes: 0
Received 5 Likes on 5 Posts
Default

Originally Posted by JDM_Stig
take picture of where the meter is and any other consumer units you have in the extension.
The meter is outside and it's pissing it down
No more consumer units in the extension.
It looks to me that the big mother of a wire leads straight back to the consumer unit so I guess it goes to the fuse which is behind the plastic cover to the right of the unit
Old 04 July 2016, 09:24 PM
  #20  
Brun
Scooby Senior
Thread Starter
 
Brun's Avatar
 
Join Date: Apr 2002
Location: Harrogate
Posts: 14,229
Likes: 0
Received 5 Likes on 5 Posts
Default

Originally Posted by ALi-B
After looking at the consumer unit, this is even more essential to have a earth wire on the socket face plates.

I know it sounds like we're being **** but that comsumer unit needs to go. The bright side means you can have the RCD or RCBO in the consumer unit so you can then fit a matching spur.
Yep - all of the sockets / switches have an eat her wire to the face
Old 04 July 2016, 09:32 PM
  #21  
JDM_Stig
Scooby Regular
iTrader: (3)
 
JDM_Stig's Avatar
 
Join Date: Feb 2009
Location: Mount Weather
Posts: 5,840
Received 41 Likes on 33 Posts
Default

you need to replace the Consumer Unit asap
If you drill a cable or the lawn mower chews up the extension lead then you have no RCD to trip, you are trusting the overload protection to go to cut the supply, or it keep shocking you,
a RCD will disconnect within 4ms so the length of shock is much shorter( if its tested and working!)
that Consumer Unit you have installed is a like having drum brakes on a 600 bhp track car imo.
Old 04 July 2016, 09:39 PM
  #22  
Brun
Scooby Senior
Thread Starter
 
Brun's Avatar
 
Join Date: Apr 2002
Location: Harrogate
Posts: 14,229
Likes: 0
Received 5 Likes on 5 Posts
Default

Originally Posted by JDM_Stig
you need to replace the Consumer Unit asap
If you drill a cable or the lawn mower chews up the extension lead then you have no RCD to trip, you are trusting the overload protection to go to cut the supply, or it keep shocking you,
a RCD will disconnect within 4ms so the length of shock is much shorter( if its tested and working!)
that Consumer Unit you have installed is a like having drum brakes on a 600 bhp track car imo.
Forgive my lack of knowledge - those breaker things are not rcds?
Old 04 July 2016, 09:56 PM
  #23  
johned
Scooby Regular
 
johned's Avatar
 
Join Date: Jan 2010
Location: derbyshire
Posts: 2,002
Likes: 0
Received 16 Likes on 12 Posts
Default

Please do not take this personally but it is obvious you are not a qualified electrician and are messing with things you do not understand so for your safety and your family please get a qualified electrician.
Old 04 July 2016, 10:15 PM
  #24  
JAY2DRE
Scooby Newbie
 
JAY2DRE's Avatar
 
Join Date: Sep 2012
Location: croydon
Posts: 3
Likes: 0
Received 0 Likes on 0 Posts
Default

You need to get a electrician round to do a zs (earth loop impedance) test to make sure your earth is adequate otherwise if a socket develops a fault it will stay live until someone touches it!!
Old 04 July 2016, 10:25 PM
  #25  
Brun
Scooby Senior
Thread Starter
 
Brun's Avatar
 
Join Date: Apr 2002
Location: Harrogate
Posts: 14,229
Likes: 0
Received 5 Likes on 5 Posts
Default

Originally Posted by JAY2DRE
You need to get a electrician round to do a zs (earth loop impedance) test to make sure your earth is adequate otherwise if a socket develops a fault it will stay live until someone touches it!!
Originally Posted by johned
Please do not take this personally but it is obvious you are not a qualified electrician and are messing with things you do not understand so for your safety and your family please get a qualified electrician.
Not really messing - replacing a few sockets is my lot although the earth test sounds like a good shout
Old 04 July 2016, 10:28 PM
  #26  
JAY2DRE
Scooby Newbie
 
JAY2DRE's Avatar
 
Join Date: Sep 2012
Location: croydon
Posts: 3
Likes: 0
Received 0 Likes on 0 Posts
Default

Originally Posted by Brun
Not really messing - replacing a few sockets is my lot although the earth test sounds like a good shout
Definitely worth is mate as you don't have a rcd
Old 04 July 2016, 11:07 PM
  #27  
JDM_Stig
Scooby Regular
iTrader: (3)
 
JDM_Stig's Avatar
 
Join Date: Feb 2009
Location: Mount Weather
Posts: 5,840
Received 41 Likes on 33 Posts
Default

Originally Posted by Brun
Forgive my lack of knowledge - those breaker things are not rcds?
No resettable fuses, and very old at that, thesework from thermal overload, so need there to be a short or high current demand to disconnect the supply,
Rcd's sense an imbalance in the phases and disconnect a lot quicker,


As mentioned get a qualified electrician in to change the one you have,
They will also check your earthing is all up to date to things like the incoming gas and water.
Old 04 July 2016, 11:10 PM
  #28  
Brun
Scooby Senior
Thread Starter
 
Brun's Avatar
 
Join Date: Apr 2002
Location: Harrogate
Posts: 14,229
Likes: 0
Received 5 Likes on 5 Posts
Default

Originally Posted by JDM_Stig
No resettable fuses, and very old at that, thesework from thermal overload, so need there to be a short or high current demand to disconnect the supply,
Rcd's sense an imbalance in the phases and disconnect a lot quicker,


As mentioned get a qualified electrician in to change the one you have,
They will also check your earthing is all up to date to things like the incoming gas and water.
Old 04 July 2016, 11:15 PM
  #29  
jaygsi
Scooby Regular
iTrader: (46)
 
jaygsi's Avatar
 
Join Date: Apr 2007
Location: uk
Posts: 14,530
Received 256 Likes on 222 Posts
Default

Don't need any 12v spot lights do you?
Old 05 July 2016, 12:08 AM
  #30  
Brun
Scooby Senior
Thread Starter
 
Brun's Avatar
 
Join Date: Apr 2002
Location: Harrogate
Posts: 14,229
Likes: 0
Received 5 Likes on 5 Posts
Default

Originally Posted by jaygsi
Don't need any 12v spot lights do you?
Not that I know of - why?


Quick Reply: Electrical socket help....



All times are GMT +1. The time now is 08:15 AM.