Question Quick question for Plumbers/Heating Engineers

I'll keep this brief.

We have a four bedroom flat on one level and we have a Worcester combi boiler.

There are two problems and I wanted to get idea of what may be wrong or if anyone had any ideas of anything I could adjust/change to help remedy the problems. The boiler is located in the kitchen which is at the back of the flat.

Firstly, the radiators at the front of the flat do not get hot. They have thermostatic valves fully open, are bled etc... the hot water in the pipes does not seem to quite reach them... the pipes themselves get warmish, but close to hot?

Secondly, the temperature of the domestic hot water is great in the kitchen where the boiler is and for almost all of the day fantastic in the rest of the flat. But, if anyone wants to have a shower/bath late in the evening it seems to generally not get all that hot... the bathrooms are located at the front of the flat. I generally have a shower in the morning and the water temperature seems fine in the morning.

Any thoughts/suggestions would be appreciated

Thanks
Old 18 February 2008, 02:48 PM
  #2  
Brendan Hughes
Scooby Regular
 
Brendan Hughes's Avatar
 
Join Date: Oct 2000
Location: same time, different place
Posts: 11,313
Likes: 0
Received 4 Likes on 2 Posts
Default

I suggest you post this in the DIY section

Mog is a Worcester expert
Old 18 February 2008, 03:05 PM
  #3  
stilover
Scooby Regular
 
stilover's Avatar
 
Join Date: May 2005
Location: Here, There, Everywhere
Posts: 10,619
Likes: 0
Received 0 Likes on 0 Posts
Default

Move
Old 18 February 2008, 10:15 PM
  #4  
Mog
Scooby Regular
 
Mog's Avatar
 
Join Date: May 2001
Location: Suffolk, very near Adnams !!
Posts: 2,860
Likes: 0
Received 0 Likes on 0 Posts
Default

The radiator problem depending on the size of your flat sounds like the pipework is too small or the pump inside the boiler is clogged/giving up.

The hot water issue is more difficult, is the hot water temp related to when the heating is on ?????

Which Worcester have you got.

mog
Old 19 February 2008, 12:24 AM
  #5  
mplaczek
Scooby Regular
Thread Starter
 
mplaczek's Avatar
 
Join Date: Jan 2004
Posts: 243
Likes: 0
Received 0 Likes on 0 Posts
Default

Originally Posted by Mog
The radiator problem depending on the size of your flat sounds like the pipework is too small or the pump inside the boiler is clogged/giving up.

The hot water issue is more difficult, is the hot water temp related to when the heating is on ?????

Which Worcester have you got.

mog
Hi Mog, Thanks for the post....

We have a Worcester 24CDi

Yes it could be that the pipework is too small... the piping for the rads runs above the floors at skirting level. Thus the previous owners had the piping in the more discreet 9mm stuff. Is there anything that can be done now to remedy this without serious works?


As for the hot water, we have had the heating on for the majority of the winter, at least at a low level. Would the heating limit the hot water? I thought about that, as in the evening, presumably when the temperature is dropping there could be a greater demand on the heating... but I did not understand why the water in the kitchen would still be really hot.

Thanks
Old 19 February 2008, 12:30 PM
  #6  
Mog
Scooby Regular
 
Mog's Avatar
 
Join Date: May 2001
Location: Suffolk, very near Adnams !!
Posts: 2,860
Likes: 0
Received 0 Likes on 0 Posts
Default

It sounds like pipework then which means replacing with the correct size 15/22mm.

I would get the gas working pressure checked when the hot water is running by a Corgi engineer.

I take it the bathroom is a fair distance from the boiler, if so then temp fluctuations maybe caused by light scaling in the plate heat exchanger.

mog
Old 19 February 2008, 03:20 PM
  #7  
mplaczek
Scooby Regular
Thread Starter
 
mplaczek's Avatar
 
Join Date: Jan 2004
Posts: 243
Likes: 0
Received 0 Likes on 0 Posts
Thumbs up

Thank you very much for the help Mog...

It is always really useful to be armed with a little information before calling someone out.

Yes, the bathroom is quite far away.

Is there anything else I can check easily to help better diagnose the problem?

Thanks
Old 19 February 2008, 03:52 PM
  #8  
Mog
Scooby Regular
 
Mog's Avatar
 
Join Date: May 2001
Location: Suffolk, very near Adnams !!
Posts: 2,860
Likes: 0
Received 0 Likes on 0 Posts
Default

I think now is the time to call out a Corgi Engineer, the main problem you will have is finding a good one, try and get a recomendation if you can.

Mog
Old 19 February 2008, 05:04 PM
  #9  
Ringpeas
Scooby Regular
 
Ringpeas's Avatar
 
Join Date: Oct 2002
Location: Grimsby
Posts: 7,961
Likes: 0
Received 0 Likes on 0 Posts
Default

You might have an airlock in the radiator pipes.
The Rads may also just need balancing.

Both caused similar problems in my house
Old 20 February 2008, 07:17 AM
  #10  
mplaczek
Scooby Regular
Thread Starter
 
mplaczek's Avatar
 
Join Date: Jan 2004
Posts: 243
Likes: 0
Received 0 Likes on 0 Posts
Default

Originally Posted by Ringpeas
You might have an airlock in the radiator pipes.
The Rads may also just need balancing.

Both caused similar problems in my house
Great, thanks for that... I'll check on that too.
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Peedee
General Technical
14
25 October 2018 09:55 PM
bugeye269
General Technical
2
27 September 2015 11:05 PM
scooby_impreza
General Technical
3
21 September 2015 09:08 PM
Bingerz1981
General Technical
1
15 September 2015 10:03 PM
malcs scooby
General Technical
1
12 September 2015 06:12 PM



Quick Reply: Quick question for Plumbers/Heating Engineers



All times are GMT +1. The time now is 10:13 AM.