Notices
Computer & Technology Related Post here for help and discussion of computing and related technology. Internet, TVs, phones, consoles, computers, tablets and any other gadgets.

speed issues 100mb circuit upstream / downstream ?

Thread Tools
 
Search this Thread
 
Old Aug 16, 2007 | 04:43 PM
  #1  
jase555's Avatar
jase555
Thread Starter
Scooby Regular
 
Joined: Apr 2000
Posts: 1,209
Likes: 0
Default speed issues 100mb circuit upstream / downstream ?

any ideas folks

bt just put in a 100mb fibre circuit , according to them they have tested it and say fine.

My problem between the 2 sites

upstream - 80mb (random tests)

downstream - 4mb (random tests)

have tried all options swapping out cables / crossover / changing switches ./ direct link to bt les 100 box

all still the same results

any ideas

jas
Reply
Old Aug 16, 2007 | 05:56 PM
  #2  
rogp's Avatar
rogp
Scooby Regular
 
Joined: Mar 2003
Posts: 455
Likes: 0
Default

Sounds like you are being very logical but have you tried something as simple as checking that any switch ports are manually set rather than 'auto'.

We had a circuit that was showing CRC errors caused by just that and it was crippling the TCP throughput, presumably becuase of the error checking overhead?
Reply
Old Aug 17, 2007 | 12:54 PM
  #3  
Kieran_Burns's Avatar
Kieran_Burns
Scooby Regular
iTrader: (1)
 
Joined: Jul 2004
Posts: 10,208
Likes: 0
From: There on the stair
Default

auto 'tends' to negotiate to 100 half duplex. you may find one end set toFULL and one to HALF this would cause all sorts of errors.

check there first
Reply
Old Aug 17, 2007 | 03:06 PM
  #4  
Stev's Avatar
Stev
Scooby Regular
 
Joined: May 2001
Posts: 47
Likes: 0
From: Edinburgh (outskirts)
Default

It is a few years since I have had any dealings with LES100's but iirc auto negotiate is not supported on the circuit and like Rogp and Kieran I suspect there could be an auto negotiate issue here .If auto negotiate is set at one end on your switch it is more than likely your switch at that end will be running at half duplex and at 10mb/s not 100mb/s when it fails to negotiate the settings with the NTE on the LES100.
Reply
Old Aug 17, 2007 | 03:12 PM
  #5  
Stev's Avatar
Stev
Scooby Regular
 
Joined: May 2001
Posts: 47
Likes: 0
From: Edinburgh (outskirts)
Default

Meant to add to above that if you are happy with your equipment settings and get the same results when connected directly to the NTE ask BT to check the NTE settings, which I am sure they can do remotely on the LES100.
Reply
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
JimBowen
ICE
5
Jul 2, 2023 01:54 PM
KAS35RSTI
Subaru
27
Nov 4, 2021 07:12 PM
blackieblob
ScoobyNet General
2
Oct 2, 2015 05:34 PM
Ganz1983
Subaru
5
Oct 2, 2015 09:22 AM
M4RKG
General Technical
3
Sep 30, 2015 07:51 PM




All times are GMT +1. The time now is 08:19 AM.