Notices
General Technical
Sponsored by:
Sponsored by: CARiD

Problem with my hatch, advice please.

Old Jan 30, 2016 | 03:35 PM
  #31  
Jack rod's Avatar
Jack rod
Thread Starter
Scooby Regular
 
Joined: Mar 2013
Posts: 130
Likes: 0
From: Rossendale
Default

Consider them renewed, thanks for all your help guys much appreciated seriously, I owe you a pint.
Reply
Old Jan 30, 2016 | 03:58 PM
  #32  
rob84's Avatar
rob84
Scooby Regular
15 Year Member
iTrader: (5)
 
Joined: Jun 2006
Posts: 5,287
Likes: 12
From: somewhere out there
Default

Glad yours turned out to be a cheap fix, Ours wasn't so lucky. Always best to get the codes read if you can get to them & the fault codes can be then linked to a DTC fault finding map which suggests which areas to check first.

I'd keep an eye on it as there may be an underlying cause to blow that fuse.
Reply
Old Jan 30, 2016 | 04:43 PM
  #33  
Jack rod's Avatar
Jack rod
Thread Starter
Scooby Regular
 
Joined: Mar 2013
Posts: 130
Likes: 0
From: Rossendale
Default

Yeah that's the first thing I did but no codes were displayed. And yes I agree I'm not to sure why the fuse had blown but I'll run it and see how it goes on.
Reply
Old Jan 31, 2016 | 06:07 PM
  #34  
Jack rod's Avatar
Jack rod
Thread Starter
Scooby Regular
 
Joined: Mar 2013
Posts: 130
Likes: 0
From: Rossendale
Default

So the exact fuse that had blown is a 15 amp blade fuse between points 3 and 4 in block 220 on the schematics. Would you guys shed a bit of light on what exactly that's protecting? I've tried to follow the ones you have kindly send me but they are to blurry to make it the text once I zoom in. I just want to understand why it's gone and try to correct the issue.
Reply
Old Jan 31, 2016 | 08:17 PM
  #35  
Don Clark's Avatar
Don Clark
Scooby Regular
20 Year Member
Liked
Loved
Community Favorite
 
Joined: Feb 2003
Posts: 7,841
Likes: 834
From: Harpenden
Default

Originally Posted by Jack rod
So the exact fuse that had blown is a 15 amp blade fuse between points 3 and 4 in block 220 on the schematics. Would you guys shed a bit of light on what exactly that's protecting? I've tried to follow the ones you have kindly send me but they are to blurry to make it the text once I zoom in. I just want to understand why it's gone and try to correct the issue.
Have put all the Engine Electrical System wiring diagrams for a MY08 hatch (without push start) into one pdf file...........

Engine Electrical System.pdf
Reply
Old Feb 6, 2016 | 07:50 PM
  #36  
Jack rod's Avatar
Jack rod
Thread Starter
Scooby Regular
 
Joined: Mar 2013
Posts: 130
Likes: 0
From: Rossendale
Default

So the scooby has run fine for a week and I took it out tonight and the same problem occurred. However this time the fuse in question is blowing as soon as power is supplied to the main power circuit this fuse blows instantly. When I say power supplies I mean putting the positive terminal in conact with the cable.

So it's the right hand 15 amp fuse shown in the earlier picture and it's labelled up as (unit E/G) could someone be kind enough to help me figure out exactly what is linked to this fuse so I can try and narrow the circuit down.
Reply
Old Feb 6, 2016 | 10:43 PM
  #37  
AudiMan's Avatar
AudiMan
Scooby Regular
 
Joined: Feb 2002
Posts: 840
Likes: 0
Default

I had the exact same problem last year with my hatch, took the garage weeks to find the fuse ! its been fine ever since, which doesn't really help you (sorry), but from an electrical POV sounds like there is a short, this fuse (I was told) allows current to the ecu once the immobilizer has seen and confirmed the key.
Would be really interested once you find the issue.
Reply
Old Feb 7, 2016 | 07:07 PM
  #38  
Jack rod's Avatar
Jack rod
Thread Starter
Scooby Regular
 
Joined: Mar 2013
Posts: 130
Likes: 0
From: Rossendale
Default

Just a final update to anyone who's helped me with this problem. The cause of my fuse blowing was a cable coming from the boost control solenoid which had rubbed against a bracket and broken the insulation. This in turn was resting directly onto metal causing short.

New cables have been run and protected properly to prevent the same happening again.
Reply
Old Feb 7, 2016 | 07:19 PM
  #39  
Don Clark's Avatar
Don Clark
Scooby Regular
20 Year Member
Liked
Loved
Community Favorite
 
Joined: Feb 2003
Posts: 7,841
Likes: 834
From: Harpenden
Default

Originally Posted by Jack rod
Just a final update to anyone who's helped me with this problem. The cause of my fuse blowing was a cable coming from the boost control solenoid which had rubbed against a bracket and broken the insulation. This in turn was resting directly onto metal causing short.

New cables have been run and protected properly to prevent the same happening again.

good to know you've traced the short
Reply
Old Feb 7, 2016 | 07:21 PM
  #40  
Jack rod's Avatar
Jack rod
Thread Starter
Scooby Regular
 
Joined: Mar 2013
Posts: 130
Likes: 0
From: Rossendale
Default

Thanks for you help along the way
Reply
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
WRXrowdy
Other Marques
3
May 14, 2017 09:01 AM
huzzy1
ScoobyNet General
5
Jun 30, 2012 05:19 PM
Hakon
General Technical
2
Feb 8, 2009 01:49 PM
jameskus2006
General Technical
6
Dec 19, 2006 09:16 PM
Alas
Drivetrain
4
Mar 9, 2001 07:29 PM


Thread Tools
Search this Thread

All times are GMT +1. The time now is 12:00 PM.