Hi all,

I have a Viper 480xv alarm system fitted and I would like to find out how you connect up the turbo timer function?
I beileve this function to be the channel 3 output on the alarm which from the manual states...

"A 30 (60, 90) second timed output will send a signal for 30 seconds when Channel 3 is pressed.
This output can be turned off during the 30-second period by pressing Channel 3 again"

I believe this is what im after but do i connect this to a relay or what?

The wire i need to connect to something is this one...

"H1/9 WHITE/BLUE 200 mA (-) channel output 3
This wire provides a (-) 200 mA output whenever the transmitter button(s) controlling Channel 3 is pressed."

If anyone knows it would be much appreciated?

Many Thanks

Reply
Old Jan 23, 2009 | 09:50 PM
  #2  
incarsolutions's Avatar
incarsolutions
Scooby Regular
iTrader: (12)
 
Joined: Oct 2008
Posts: 376
Likes: 0
From: dartford
Default

you need the remote start module fitted to use that function, had it on my old 200sx
Reply
Old Jan 23, 2009 | 10:31 PM
  #3  
SubaSi's Avatar
SubaSi
Thread Starter
Scooby Regular
 
Joined: Dec 2007
Posts: 164
Likes: 0
From: Dorset
Default

ummm..... thats what i had suspected!!

Cheers for the response Looks like i'm gunna have to order a remote start module!
Reply
Old Jan 25, 2009 | 04:51 PM
  #4  
Car Security Expert's Avatar
Car Security Expert
Scooby Regular
 
Joined: Nov 2008
Posts: 242
Likes: 0
From: UK
Default

Originally Posted by incarsolutions
you need the remote start module fitted to use that function, had it on my old 200sx
no you dont
Reply
Old Jan 26, 2009 | 10:45 AM
  #5  
incarsolutions's Avatar
incarsolutions
Scooby Regular
iTrader: (12)
 
Joined: Oct 2008
Posts: 376
Likes: 0
From: dartford
Default

you can do it the old fashioned way with a relay but if you're going to go to the trouble of that why not have the convenience of remote start too??
most shops will charge about £80 to wire the relay in place when for £150 you can have it starting too
Reply
Old Jan 26, 2009 | 12:25 PM
  #6  
Car Security Expert's Avatar
Car Security Expert
Scooby Regular
 
Joined: Nov 2008
Posts: 242
Likes: 0
From: UK
Default

the turbo timer function can be wired in for about £50 by most security shops.
Reply
Old Feb 2, 2009 | 03:49 PM
  #7  
audioscape's Avatar
audioscape
Scooby Regular
 
Joined: Jan 2009
Posts: 315
Likes: 0
From: buckinghamshire
Default

it is easy done with a 5 pin relay on the timed output of the alarm if you go this route make sure they wire the neg on the relay via the neg of the handbrake. this will make sure a that the car should not go anywhere and b if someone sees it running jumps in and puts the handbrake down the car will stop. this is one way we used to fit it in cliffords. just test it has been fitted this way before you take the car away from the dealer.
Reply

Trending Topics

Old Feb 2, 2009 | 05:46 PM
  #8  
Car Security Expert's Avatar
Car Security Expert
Scooby Regular
 
Joined: Nov 2008
Posts: 242
Likes: 0
From: UK
Default

You cant wire the negative from the relay to the handbrake because it wouldn't work at all. And thats with both Clifford and Viper.
Reply
Old Feb 2, 2009 | 05:51 PM
  #9  
audioscape's Avatar
audioscape
Scooby Regular
 
Joined: Jan 2009
Posts: 315
Likes: 0
From: buckinghamshire
Default

done it do u know gary roberts when he used to work for clifford he can confirm it. now driven marketing
Reply
Old Feb 2, 2009 | 06:02 PM
  #10  
audioscape's Avatar
audioscape
Scooby Regular
 
Joined: Jan 2009
Posts: 315
Likes: 0
From: buckinghamshire
Default

Originally Posted by Car Security Expert
You cant wire the negative from the relay to the handbrake because it wouldn't work at all. And thats with both Clifford and Viper.

relay 1 pin 30 perm live fused 1 amp
pin 85 perm live fused same as above
pin 86 neg timedout at 500 ma from alarm
pin 87 switched live out ro second relay pin 86
relay2 pin 85 handbrake
pin 30 perm live fused 30 amp
pin 87 output to ignition

sorry forgot to say clifford used to send all there problem installations to us to sort out

Last edited by audioscape; Feb 2, 2009 at 06:03 PM.
Reply
Old Feb 5, 2009 | 10:49 AM
  #11  
Car Security Expert's Avatar
Car Security Expert
Scooby Regular
 
Joined: Nov 2008
Posts: 242
Likes: 0
From: UK
Default

thats using 2 relays. Not 1 like you said previously
Reply
Old Feb 5, 2009 | 03:39 PM
  #12  
audioscape's Avatar
audioscape
Scooby Regular
 
Joined: Jan 2009
Posts: 315
Likes: 0
From: buckinghamshire
Default

i did not want to give all secrets away but oh well why not i have done it with a single universal cl relay as well.
Reply
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
KAS35RSTI
Subaru
27
Nov 4, 2021 07:12 PM
Ganz1983
Subaru
5
Oct 2, 2015 09:22 AM
thunder8
General Technical
0
Oct 1, 2015 09:13 PM
madmover
Member's Gallery
4
Sep 28, 2015 10:46 AM


Thread Tools
Search this Thread

All times are GMT +1. The time now is 02:23 PM.