Old Dec 7, 2002 | 10:18 AM
  #1  
BHORT's Avatar
BHORT
Thread Starter
Scooby Regular
 
Joined: Apr 1999
Posts: 271
Likes: 0
Question

Does having my hot water get hotter and hotter with the central heating on likely to mean that the 3 way diverter valve is broken? I notice that when moving the diverter valve's lever there is no resistance in either direction. Can you just turn off the electricity and swap the whole valve?

Brendan
Reply
Old Dec 7, 2002 | 02:35 PM
  #2  
AnDy_PaNdY's Avatar
AnDy_PaNdY
Scooby Regular
 
Joined: Aug 2002
Posts: 541
Likes: 0
Post

The small motor inside the diverter unit has probably burnt out.
I replaced mine last year. It's a simple job. Get yourself a replacement from Wicks.
Best of luck.
Reply
Old Dec 7, 2002 | 03:24 PM
  #3  
dsmith's Avatar
dsmith
Scooby Regular
 
Joined: Mar 1999
Posts: 4,518
Likes: 0
Post

if the water gets hotter and hotter then your cylinder thermostat may be buggered......
Reply
Old Dec 7, 2002 | 03:33 PM
  #4  
Bee's Avatar
Bee
Scooby Regular
 
Joined: Jan 2002
Posts: 621
Likes: 0
Lightbulb

Brendon, More than likely the valve's the prob mate.

Should be a silver box on the valve yeah, this is the motor head.

I take it you've had the cover off it and can see the motor??

What to do is have a look on the BASE of the silver box. If there are 2 x Brass screws DIAGONALLY from each other you can buy a new HEAD only BUT if there are 4 x screws (One each corner) you'll need a whole valve

Have fun!

- Bee.
Reply
Old Dec 7, 2002 | 03:52 PM
  #5  
hades's Avatar
hades
Scooby Regular
 
Joined: Jun 2002
Posts: 2,905
Likes: 0
From: From Kent to Gloucestershire to Berkshire
Post

No resistance to lever suggests something is knackered in the valve. Apart from Bee's comments, it is possible that the actual valve itself has seized in which case you will need to change it all rather than just the actuator. Much more likely it is just the motor/actuator, IMHO.

Whole new valve = either shut down system and pipe freeze, or shut down system and drain it Actuator only = pull the right fuse and takes 10 minutes.

I got away with actuator only, and was pleased about that!
Reply
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Mattybr5@MB Developments
Full Cars Breaking For Spares
28
Dec 28, 2015 11:07 PM
Mattybr5@MB Developments
Full Cars Breaking For Spares
12
Nov 18, 2015 07:03 AM
TylerD529
General Technical
2
Oct 9, 2015 01:53 AM
Ganz1983
Subaru
5
Oct 2, 2015 09:22 AM
Pro-Line Motorsport
Car Parts For Sale
2
Sep 29, 2015 07:36 PM


Thread Tools
Search this Thread

All times are GMT +1. The time now is 01:16 PM.