Simple Wiring Diagram

Old Jan 10, 2002 | 12:14 PM
  #1  
alcazar's Avatar
alcazar
Thread Starter
Scooby Regular
20 Year Member
Liked
Loved
Community Favorite
iTrader: (2)
 
Joined: Jun 2002
Posts: 40,788
Likes: 30
From: Rl'yeh
Thumbs up

Depending on your PIR, there may be one in the box.
Two lights from one PIR is easy, just run two seperate wires, one to each light, or, if they're both in the same direction from the PIR, connect PIR to one, then from that one to the next, ie: two wires in each hole at the "first" light's connector block.
As regards premanently on, you need a lightswitch(!!!), take a Positive (live) feed to it from the same place you're getting the feed for the PIR, then from the other side of this switch, to the terminal on the PIR marked "Load".
Hope this is of help, I can't do "Paintshop", I'm a computer moron, or so my 16 year old says!!!
I reckon it's better than just being a moron though..............
:
Alcazar

[Edited by alcazar - 10/1/2002 12:14:47 PM]
Reply
Old Oct 1, 2002 | 08:18 AM
  #2  
Puff The Magic Wagon!'s Avatar
Puff The Magic Wagon!
Moderator
25 Year Member
iTrader: (2)
 
Joined: May 2000
Posts: 16,980
Likes: 15
From: From far, far away...
Cool

Trying to install 2x500w lights both "comanded" by one PIR.

Also want to have an "always on" switch as well.

Any 'trician be able to do me a simple +ve / -ve type diagram please?

Paintshop is ideal

Thanks



(Wife doesn't trust me )
Reply
Old Oct 1, 2002 | 12:25 PM
  #3  
David_Wallis's Avatar
David_Wallis
Scooby Regular
 
Joined: Nov 2001
Posts: 15,239
Likes: 1
From: Leeds - It was 562.4bhp@28psi on Optimax, How much closer to 600 with race fuel and a bigger turbo?
Post

Just make sure the relay in the first floodlight is capable of switching 4.16 Amps..

Watts / Volts = Amps

1000 / 240 = 4.16

If it is then Supply the first light with three core and earth lighting wire... wiring it as normal then use the second wire to provide a switched live, and then connect the other light across this floodlights bulb connection in parallel... this is easier on some floodlights than others...

What connections can you get to.. .do you just have L E N ?? or do you have others?

David
Reply
Old Oct 1, 2002 | 01:32 PM
  #4  
Puff The Magic Wagon!'s Avatar
Puff The Magic Wagon!
Moderator
25 Year Member
iTrader: (2)
 
Joined: May 2000
Posts: 16,980
Likes: 15
From: From far, far away...
Post

David

It has only LEN with a cable in for power & a cable out for lamps (shared earth, shared neutral, live a-piece). Max rating is 2000W incandescant & 600W flourescent.

So what I need to do is to run a closure switch that by-passes the PIR (to the lives of each cable) to have an always on over-ride?
Reply
Old Oct 1, 2002 | 02:02 PM
  #5  
David_Wallis's Avatar
David_Wallis
Scooby Regular
 
Joined: Nov 2001
Posts: 15,239
Likes: 1
From: Leeds - It was 562.4bhp@28psi on Optimax, How much closer to 600 with race fuel and a bigger turbo?
Post

yup.. wire it in as normal with a three core and earth (then you should have one spare... connect this to the live out... then daisy chain the other light (without pir) across the live out and shared neutral and earth... then where you find the power for your floodlight... say in the kitchen with a fused outtlet... wire a switch across from the live supply to the spare wire in the three core...

Make sense?

David
Reply
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
JimBowen
ICE
5
Jul 2, 2023 01:54 PM
T.K
General Technical
10
Oct 2, 2015 11:35 AM
sti 360
General Technical
6
Oct 2, 2015 09:39 AM
mistermexican
General Technical
2
Oct 1, 2015 04:30 PM
Flat4x4-again
General Technical
2
Sep 29, 2015 06:32 PM


Thread Tools
Search this Thread

All times are GMT +1. The time now is 08:32 PM.