Notices
General Technical
Sponsored by:
Sponsored by: CARiD

MY03 wrx ppp middle exhaust section

Thread Tools
 
Search this Thread
 
Old Apr 2, 2009 | 04:57 PM
  #1  
matttrig's Avatar
matttrig
Thread Starter
Scooby Regular
 
Joined: Jan 2009
Posts: 86
Likes: 0
From: sevenoaks
Default MY03 wrx ppp middle exhaust section

does it have a cat in the middle section, or is the big bulge a resinator box or something? ive ahd the down pipe cat removed and i dont want anything else getting in the way.
Reply
Old Apr 2, 2009 | 09:51 PM
  #2  
daz1968's Avatar
daz1968
Scooby Regular
iTrader: (13)
 
Joined: Jun 2007
Posts: 2,481
Likes: 0
Default

the cat removal pipe on a ppp still retains the heat shields so looks the same from a casual glance as the standard pipe, if you are on about the bulge in the long centre section this is a resonator box and this can be replaced with a non resonated centre section, it adds a bit of noise but unsure if it actually makes any performance difference. The biggest restriction if it is a wrx ppp is the cat in the up pipe and this can be replaced with either an sti up pipe or an aftermarket stainless pipe, although allow a fair amount of time if you are fitting this yourself, took me about 4 hours to do up pipe and down pipe due to awkwardness of undoing the bolts and nuts.

Last edited by daz1968; Apr 2, 2009 at 09:53 PM.
Reply
Old Apr 3, 2009 | 06:52 AM
  #3  
matttrig's Avatar
matttrig
Thread Starter
Scooby Regular
 
Joined: Jan 2009
Posts: 86
Likes: 0
From: sevenoaks
Default

Ok, ive had the down pipe replaced and that was covered in heat shields and has got a cat in it, is there another cat in the up pipe then ?
Reply
Old Apr 3, 2009 | 07:43 PM
  #4  
fasterdad's Avatar
fasterdad
Scooby Regular
 
Joined: Aug 2008
Posts: 79
Likes: 0
Default

yes
Reply
Old Apr 3, 2009 | 10:38 PM
  #5  
FLAT ERIC's Avatar
FLAT ERIC
Scooby Regular
iTrader: (1)
 
Joined: Dec 2001
Posts: 7,327
Likes: 0
From: You only live ONCE But if you do it right >>>>> ONCE is enough
Smile

Originally Posted by matttrig
Ok, ive had the down pipe replaced and that was covered in heat shields and has got a cat in it, is there another cat in the up pipe then ?
Yes so you need these which are what I have on my ex-PPP'd MY03 WRX :-

H&S Up pipe




H&S Centre pipe straight through



If you have the PPP you should already have this short section & backbox

Reply
Old Apr 3, 2009 | 10:43 PM
  #6  
adehook's Avatar
adehook
Scooby Regular
 
Joined: Jan 2009
Posts: 340
Likes: 0
From: wolverhampton
Default

be it will be loud as **** with those 2 pipes fitted
Reply
Old Apr 3, 2009 | 10:44 PM
  #7  
adehook's Avatar
adehook
Scooby Regular
 
Joined: Jan 2009
Posts: 340
Likes: 0
From: wolverhampton
Default

anyone got a link to prices?
Reply
Old Apr 3, 2009 | 11:04 PM
  #8  
FLAT ERIC's Avatar
FLAT ERIC
Scooby Regular
iTrader: (1)
 
Joined: Dec 2001
Posts: 7,327
Likes: 0
From: You only live ONCE But if you do it right >>>>> ONCE is enough
Smile

Originally Posted by adehook
be it will be loud as **** with those 2 pipes fitted


Oh yes. Even louder when you ditch the Prodrive backbox like I have & stick one of these on the back :-






Link to prices
Reply
Old Apr 4, 2009 | 08:53 AM
  #9  
daz1968's Avatar
daz1968
Scooby Regular
iTrader: (13)
 
Joined: Jun 2007
Posts: 2,481
Likes: 0
Default

I have decat up pipe ppp sportcat downpipe and centre decat, H&S de res centre section but retained the ppp backbox and it is not to loud at all.
Reply
Old Apr 5, 2009 | 09:24 PM
  #10  
FLAT ERIC's Avatar
FLAT ERIC
Scooby Regular
iTrader: (1)
 
Joined: Dec 2001
Posts: 7,327
Likes: 0
From: You only live ONCE But if you do it right >>>>> ONCE is enough
Smile

Originally Posted by daz1968
I have decat up pipe ppp sportcat downpipe and centre decat, H&S de res centre section but retained the ppp backbox and it is not to loud at all.
That's why in the end I took my PPP backbox off. I got used to it & it started to sound too quiet for me.
Reply
Old Apr 6, 2009 | 12:51 AM
  #11  
antscooby's Avatar
antscooby
Scooby Regular
 
Joined: Apr 2009
Posts: 68
Likes: 0
From: suffolk born n bread
Default

i had a hayward n scott down pipe, custom made straight through center sec and a blitz nur spec back box and i hardly ever heard anything louder. LOVED IT, oh and i made a flamer kit and it worked a treat, and it was 1 which didnt use the coil cut out, got some fooking HUGE flames.
Reply
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Scott@ScoobySpares
Full Cars Breaking For Spares
7
Dec 14, 2015 08:16 AM
ben.harris
General Technical
7
Sep 23, 2015 03:55 PM
Danny0608
Subaru Parts
0
Sep 12, 2015 02:59 PM




All times are GMT +1. The time now is 06:16 AM.