Notices
Drivetrain Gearbox, Diffs & Driveshafts etc

removing up pipe cat

Thread Tools
 
Search this Thread
 
Old 12 January 2004, 07:13 PM
  #1  
^OPM^
Scooby Regular
Thread Starter
 
^OPM^'s Avatar
 
Join Date: Dec 2001
Location: just simple old me
Posts: 2,170
Likes: 0
Received 0 Likes on 0 Posts
Post

i read a post on here a bit ago that said u shouldn't tune a MY01 impreza up without removing the cat in the up pipe as it can break then go into ur turbo etc obviously breaking it,is this rite as i see scoobyclinic is advertising a tune up to get to 285 bhp and im interestd but obviously i dont want to risk knackering my turbo up? any help please
Old 12 January 2004, 10:58 PM
  #2  
JIM THEO
Scooby Regular
 
JIM THEO's Avatar
 
Join Date: Oct 2001
Posts: 1,833
Likes: 0
Received 0 Likes on 0 Posts
Post

From what have read it's true but replacing it with a cat free up pipe may cause also your EGT sensor to disintegrate and destroy your turbo not to say your engine so it's better to replace the sensor with a bolt and put a 2,2KOhm - 1/2Watt in place of it.
I'll try first my up pipe with the EGT bolted just to monitor EGT with full decat and (hope before it fails) I replace it with a bolt soon.
I am also interested to hear more comments from the professionals (say H&S, Scoobysport, TSL, Bob, Pat etc) as they have a lot of experience about - how many EGTs have disintegrated and have they caused any problem in turbo or engine?
Local Subaru service have only one case with broken EGT sensor but it was completely disintegrated at once without cause any problem!!!
JIM

[Edited by JIM THEO - 1/12/2004 11:00:22 PM]
Old 13 January 2004, 08:43 AM
  #3  
ZIPPY
Scooby Regular
 
ZIPPY's Avatar
 
Join Date: Dec 2001
Posts: 1,780
Likes: 0
Received 0 Likes on 0 Posts
Post

Interesting Theo,yes they do tend to fail after the up-pipe cat is removed but i've never heard of one completely disintegrating.

The 2.2k resistor does cure the CEL light but if you have a re-map (Ecutek 3) i have heard that the values are adjusted for the EGT sensor to prevent it failing so you can leave it in place.

My EGT sensor failled and i still have my cats in place but i believe a faulty batch was the problem.

Zippy
Old 16 January 2004, 10:26 AM
  #4  
^OPM^
Scooby Regular
Thread Starter
 
^OPM^'s Avatar
 
Join Date: Dec 2001
Location: just simple old me
Posts: 2,170
Likes: 0
Received 0 Likes on 0 Posts
Post

.
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Pro-Line Motorsport
Car Parts For Sale
48
21 July 2017 09:50 PM
Tarling
Subaru Parts
10
19 October 2015 07:58 PM
Manford
Lighting and Other Electrical
5
02 October 2015 07:51 PM
S600HBY
Subaru Parts
0
25 September 2015 09:46 AM



Quick Reply: removing up pipe cat