Notices
General Technical
Sponsored by:
Sponsored by: CARiD

Uprated fuel pump

Thread Tools
 
Search this Thread
 
Old Jun 9, 2002 | 02:20 PM
  #1  
DodgeT's Avatar
DodgeT
Thread Starter
Scooby Regular
 
Joined: Feb 2002
Posts: 605
Likes: 0
Question

Are any of you running an uprated fuel pump, who did you buy it from, what sort of cost etc???

MY94 uk turbo running 18psi. Do i need one????
Reply
Old Jun 9, 2002 | 10:50 PM
  #2  
David_Wallis's Avatar
David_Wallis
Scooby Regular
 
Joined: Nov 2001
Posts: 15,239
Likes: 1
From: Leeds - It was 562.4bhp@28psi on Optimax, How much closer to 600 with race fuel and a bigger turbo?
Post

Yes, Yes, and I got it from Mark on here (R19KET)... Send he a mail and if your nice to him, he may have some left!

David
Reply
Old Jun 11, 2002 | 07:52 PM
  #3  
JIM THEO's Avatar
JIM THEO
Scooby Regular
 
Joined: Oct 2001
Posts: 1,833
Likes: 0
Question

[b]David
Could you tell me please something about your new pump as I have also bought one from Mark but haven't yet fitted?
From what I can see the Walbro GSS341 pump has on the top two small terminals without any connection on them. There is no short-circuit danger if/when the fuel wets the terminals as they are negative and positive poles?
The pump has also the top outlet reverse to the original outlet, will it needs slight bend in order to fit straight to the fuel rail?
Thanks in advance.
JIM
Reply
Old Jun 11, 2002 | 08:10 PM
  #4  
JamesS's Avatar
JamesS
Scooby Regular
 
Joined: Jul 1999
Posts: 821
Likes: 0
Post

Jim,

Electrical terminals same as OEM pump on mine.

OEM leads are `open` at the top as well.

The top of the pump was `reversed` on mine as well. I cut a bit off the pick-up pipe so the rubber pipe runs in an S.

The OEM pumps vary year to year. A 97MY I know had one twice the diameter of the FSE one!

Running no worries!
Reply
Old Jun 11, 2002 | 08:41 PM
  #5  
R19KET's Avatar
R19KET
Scooby Regular
 
Joined: May 1999
Posts: 2,637
Likes: 0
From: SSO2003 2nd, SSO2005 1st, SSO2006 2nd, TACC Rd4 5th 4wd: In my car ;-)
Post

Just a quick note:

There appears to be two types of pump fitted to our cars, and it seems that there is no way of telling which one you have, until the original pump is removed.

So far, no one has had a problem fitting the FSE/Walbro pump, but some people have had to "tweek" the pipe as described.

If anyone is really concerned, the option is to remove your pump first, take a note of the pipe position, then replace the pump, and let the supplier know. There is an alternative pump available, but I doubt it's worth going through the hassle, to find out.

Mark.
Reply
Old Jun 11, 2002 | 09:07 PM
  #6  
David_Wallis's Avatar
David_Wallis
Scooby Regular
 
Joined: Nov 2001
Posts: 15,239
Likes: 1
From: Leeds - It was 562.4bhp@28psi on Optimax, How much closer to 600 with race fuel and a bigger turbo?
Post

To be honest, I havent fitted it yet so couldnt tell you... its still on the bench... No there is no danger of the fuel shorting it out at that voltage, however ensure you make the connections properly... my replacement has a plug and flying lead... these will be soldered and heat shrunk if need be... but ill test the heatshrink in some petrol first... and wont heat near the tank!

Shouldnt be too hard to make anything fit... lots of flexy pipe and throw it in the tank

David

David
Reply
Old Jun 11, 2002 | 11:22 PM
  #7  
JIM THEO's Avatar
JIM THEO
Scooby Regular
 
Joined: Oct 2001
Posts: 1,833
Likes: 0
Wink

Thanks Mark!
I guess the fuel even with filled tank is below the middle of the pump, so it's difficult to wet the electrical connectors and terminals that are exposed, right?
Reply
Old Jun 12, 2002 | 01:06 AM
  #8  
R19KET's Avatar
R19KET
Scooby Regular
 
Joined: May 1999
Posts: 2,637
Likes: 0
From: SSO2003 2nd, SSO2005 1st, SSO2006 2nd, TACC Rd4 5th 4wd: In my car ;-)
Post

Jim,

The pump will be fully submerged when the tank is full.

The wires on the stock pump are not insulated.

Mark.
Reply
Old Jun 14, 2002 | 10:09 AM
  #9  
DJNormski's Avatar
DJNormski
Scooby Regular
 
Joined: Mar 2002
Posts: 124
Likes: 0
Smile

As JamesS pointed out, I bought one of these pumps from Mark (cheers Mark!) and I did have to modify my terminals to suit.
I have a 97/98MY and the OEM pump was twice the size of the Walbro/FSE one.
The hose connection lined up with a bit of finessing and the wiring terminals were all in the right places. However, I had to use the new fly leads supplied in Mark's kit and connect them to the old male connector. This is where soldering and heat shrink is used. I took out the pins from the male connector and cut the wires off leaving about 10-15mm of wire left on the pins. Strip the insulation off of these and clean the wires with emery cloth. Strip new fly leads and solder to suit. Shrink wrap/heat shrink right up to the pin connectors then replace pins back into male connector and 'Bob's your Uncle'!

Much improved fuelling even running standard injectors, but now I need to another bloody remap due to more % FF especially on cold start giving me Bore washing

Worth while mod if your thinking of mappable ECU's/running lean/pump sha66ed.

Jacko. hope this helps?

[Edited by DJNormski - 6/14/2002 10:12:32 AM]
Reply
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Mattybr5@MB Developments
Full Cars Breaking For Spares
28
Dec 28, 2015 11:07 PM
Mattybr5@MB Developments
Full Cars Breaking For Spares
12
Nov 18, 2015 07:03 AM
Ganz1983
Subaru
5
Oct 2, 2015 09:22 AM
shorty87
Other Marques
0
Sep 25, 2015 08:52 PM
hedgecutter
General Technical
3
Sep 25, 2015 02:35 PM




All times are GMT +1. The time now is 08:21 AM.