My pa has recently bought one of those halogen light type fittings on an aluminium type rose fitting. Says the fitting needs to be earthed. As he has no earth cable in the existing fitting what can he do or is there no way it can be fitted.

Chip.
Reply
Old Jan 2, 2002 | 05:20 PM
  #2  
fast bloke's Avatar
fast bloke
Scooby Regular
 
Joined: Nov 2000
Posts: 26,619
Likes: 0
Post

All metal light fittings should be earthed. If there is a short to the casing with no earth and you touch it, you will become the earth and glow very brightly. Might be best to get a spark to look at this as wiring with no earth is generally quite old or botched DIY job, so lots of potential for pain
Reply
Old Jan 2, 2002 | 06:17 PM
  #3  
matt.bowey's Avatar
matt.bowey
Scooby Regular
 
Joined: Apr 2001
Posts: 890
Likes: 0
Post

For gods sake make sure you earth the case!!! You will have to run another cable from the fitting to the nearest earth point!!
Reply
Old Jan 2, 2002 | 07:57 PM
  #4  
SCOBY's Avatar
SCOBY
Scooby Regular
 
Joined: Dec 2001
Posts: 629
Likes: 0
Post

The lighting feed will either go straight to the switch or to the fitting, probably to the fitting as it sounds like an old wiring job.

At the original fitting unsrew it and get a tool that will tell you whats live i.e volt stick or steinels or try to trust 1 of those screwdriver testing tools, just make sure it works on something else thats live 1st.

You then want to see if the live cable is going onto another fitting by giving it a tug. i.e linked feed,( but make sure youve turned the power off when doing this). If this is the case and theres an earth at that point then all you need to do is just tie a new length of cable onto the end (1.5 twin & Earth) of the old 1 and pull the new 1 all the way through to where the new light is going.

Youve obviously got to diconnect these from the Roses, but make sure you remember where each 1 goes back.

If this isnt the case then I would suggest 1. Full rewire cos it sounds like you aint got much earthing. Or 2. Buy another light thats hasnt got a metal base.

EASY PEASY

Good Luck
SCOBY
Reply
Old Jan 2, 2002 | 08:53 PM
  #5  
stevie c's Avatar
stevie c
Scooby Regular
 
Joined: Sep 2001
Posts: 386
Likes: 0
Arrow

dont forget that cold water pipes count as earth points too,but like said earlier,the earth will still be inside the twin and skin cable,friend just needs to pull it out and extend it,no big problem.

steve
Reply
Old Jan 2, 2002 | 09:16 PM
  #6  
SCOBY's Avatar
SCOBY
Scooby Regular
 
Joined: Dec 2001
Posts: 629
Likes: 0
Post

On very early house re-wires Earths were not found to be used that much in T&E.

Yes he can try and get some slack & strip it to c if theres an earth, but trust me all of us electricians we dont think about the next person, just get in and get out, of corse doing a good job at the same time

With regards to the bonding of water pipes, yes thats ok as long as the mains water pipes into the house have been earthed, have you ever tried getting your hand into a hole in the ceiling and strapping a bonding clamp and connecting it to a water pipe, its bloody impossible.

Hope this helps

Cheers

SCOBY
Reply
Old Jan 2, 2002 | 10:27 PM
  #7  
stevie c's Avatar
stevie c
Scooby Regular
 
Joined: Sep 2001
Posts: 386
Likes: 0
Wink

water pipe was a long shot,but you never know,how many jobs have you done and thought 'god,that was handy'?

mind you there are more jobs of the 'god,this is a bitch!' variety!

steve
Reply
Old Jan 3, 2002 | 12:16 AM
  #8  
SCOBY's Avatar
SCOBY
Scooby Regular
 
Joined: Dec 2001
Posts: 629
Likes: 0
Post

Worries me too m8, I hate touching anything that I havent installed

There are a lot of cowboys out there, as I found out the worst way.
But anyway I think this is going way over the head of the man that asked the question.

Simple answer = Leave the light up that was already there in your dads place and nick the new 1 and put in your place.

Simple

SCOBY
Reply
Old Jan 3, 2002 | 04:57 PM
  #9  
Chip's Avatar
Chip
Thread Starter
Scooby Regular
 
Joined: Feb 1999
Posts: 11,758
Likes: 0
From: Cardiff. Wales
Post

Scoby
That sounds like a good idea to me.

Chip
Reply
Old Jan 4, 2002 | 07:42 PM
  #10  
EwanS's Avatar
EwanS
Scooby Regular
 
Joined: Apr 2001
Posts: 116
Likes: 0
From: Perth and Iran
Post

Chip,
If the fitting is 12volt with the transformer remote to the fitting (plastic bullet or box)then there is no requirement to earth .
If the fitting is all in one piece, and metal - What should be earthed to the casing though, is the high tension side of the circuit. so where the mains enters the casing it should be earthed - you will find that the transformer may be earthed at the same point.
EwanS
Reply
Old Feb 1, 2002 | 11:43 PM
  #11  
cryptwalk's Avatar
cryptwalk
Scooby Regular
 
Joined: Sep 2001
Posts: 11,429
Likes: 0
From: Manchestoh!
Post

Just a quick note if you fail to bond properly all points cos it's hard to get to it, and someone die's you can be held responsable and sentenced under the electricity at work regs.

I know of a person whom got 7 years for not bonding a instalation properly, there was a fault on the central heating pump and every time it came on it put the pipes live, the fellow went back 4 times to try and find the fault unsucessfully as they were getting zapped. Unfortunatly the 21 year old son got a zap that killed him hence the fellow gettting sent down. If it had been bonded correctly at all suplimentry and main earthing points it would of
pop't the mcb/rcd/fuses/whatever.

Kinda off subject, sorry but it worrys me when jobs are half done i see it everyday.

[Edited by cryptwalk - 1/2/2002 11:48:04 PM]
Reply
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
KAS35RSTI
Subaru
27
Nov 4, 2021 07:12 PM
just me
Non Scooby Related
26
Jan 3, 2020 11:12 AM
dpb
Non Scooby Related
14
Oct 3, 2015 10:37 AM
T.K
General Technical
10
Oct 2, 2015 11:35 AM
mistermexican
General Technical
2
Oct 1, 2015 04:30 PM




All times are GMT +1. The time now is 01:49 AM.