Notices
Computer & Technology Related Post here for help and discussion of computing and related technology. Internet, TVs, phones, consoles, computers, tablets and any other gadgets.

APC UPS's

Thread Tools
 
Search this Thread
 
Old Aug 18, 2009 | 05:20 PM
  #1  
InvisibleMan's Avatar
InvisibleMan
Thread Starter
Scooby Regular
 
Joined: May 2001
Posts: 12,583
Likes: 0
From: .
Default APC UPS's

Do anyone have APC UPS's? I am connecting to one locally via serial but don't know what commands to type in hyperterminal, as usual important steps are missed out in documentation.
Reply
Old Aug 18, 2009 | 05:45 PM
  #2  
Davey P's Avatar
Davey P
Scooby Regular
iTrader: (1)
 
Joined: Aug 2002
Posts: 1,616
Likes: 0
From: Dorset
Default

All the one's I've logged into take you straight into a set of menu's and you go from there.
Reply
Old Aug 18, 2009 | 06:03 PM
  #3  
InvisibleMan's Avatar
InvisibleMan
Thread Starter
Scooby Regular
 
Joined: May 2001
Posts: 12,583
Likes: 0
From: .
Default

yes once you have the ip address set, you can log in via browser using ip or name. I dont know to use hyperterminal and the command line to use. all it says run HT, log in and away you go. so I have a HT blank window now what....
Reply
Old Aug 18, 2009 | 07:51 PM
  #4  
HHxx's Avatar
HHxx
Scooby Regular
 
Joined: Nov 2001
Posts: 2,576
Likes: 0
Default

Does that mean you haven't connected to it yet?

I can't remember the settings, should be in the manual...

Something like:
9600 baud
8 bits
No parity
1 stop bit
no flow control

And pick the correct com port.

Once you are connected with HT, there should be a menu system to navigate and configure it.
Reply
Old Aug 18, 2009 | 10:09 PM
  #5  
Davey P's Avatar
Davey P
Scooby Regular
iTrader: (1)
 
Joined: Aug 2002
Posts: 1,616
Likes: 0
From: Dorset
Default

I think the baud needs to be 2400.

Just to add I access using Putty.
Reply
Old Aug 18, 2009 | 11:53 PM
  #6  
darlodge's Avatar
darlodge
Scooby Regular
 
Joined: Oct 2001
Posts: 3,449
Likes: 0
From: Lovely Lancing in West Sussex
Default

Most of the newer APC Controller cards grab a DHCP address when connected to the LAN and then you control everything over the web interface.

Darren
Reply
Old Aug 19, 2009 | 01:05 PM
  #7  
InvisibleMan's Avatar
InvisibleMan
Thread Starter
Scooby Regular
 
Joined: May 2001
Posts: 12,583
Likes: 0
From: .
Default

yup thats what i mean about the documentation. first it says 9600 then down the line its 2400. so have tried both.
I have an older one and newer one and have tried local connection and entering the dns ip and grabbing dhcp.
I have since been able to get HT to connect so i have the flashing icon but im supposed to be able to type a Y to get a SM reply to show connection but I cant type anything. Am i supposed to open a telnet session after this and type from here?

Also im using a xp laptop to connect, how can i tell if something else is using the com port, where do i check?

Anyways have emailed their support again not to send me their web links of the same stuff i've said i had already done prior to emailing them the first time....
Reply
Old Aug 19, 2009 | 08:23 PM
  #8  
HHxx's Avatar
HHxx
Scooby Regular
 
Joined: Nov 2001
Posts: 2,576
Likes: 0
Default

Can't you factory reset it?

If you connected to the correct COM port, just hit enter and it should then display the menu. If the COM port is in use by another application, HT should not let you connect to it, I think..

Which card are you using? Some of the older ones had no web interface and those you can only communicate with via SNMP over ethernet (HT over serial still works)

You are using the correct serial cable? It uses a specially wired one. Normal serial cables will just make the UPS reset power constantly. Done that once
Reply
Old Aug 19, 2009 | 09:22 PM
  #9  
hodgy0_2's Avatar
hodgy0_2
Scooby Regular
15 Year Member
Liked
Loved
Community Favorite
 
Joined: Jul 2008
Posts: 15,634
Likes: 22
From: K
Default

the APC software will usually try and make the connection using all the possible variable re baud rate com ports

be careful older versions had a bug in the Java licencing code contained in the windows service which would hang the server on a reboot
Reply
Old Aug 20, 2009 | 10:20 AM
  #10  
Davey P's Avatar
Davey P
Scooby Regular
iTrader: (1)
 
Joined: Aug 2002
Posts: 1,616
Likes: 0
From: Dorset
Default

Originally Posted by HHxx

If you connected to the correct COM port, just hit enter and it should then display the menu. If the COM port is in use by another application, HT should not let you connect to it, I think..
That is correct.
Reply
Old Aug 21, 2009 | 10:31 AM
  #11  
InvisibleMan's Avatar
InvisibleMan
Thread Starter
Scooby Regular
 
Joined: May 2001
Posts: 12,583
Likes: 0
From: .
Default

not sure about hanging the server on a reboot but connecting the APC provided com cable causes it to power off....and all the file servers in that rack
Reply
Old Aug 27, 2009 | 03:26 PM
  #12  
InvisibleMan's Avatar
InvisibleMan
Thread Starter
Scooby Regular
 
Joined: May 2001
Posts: 12,583
Likes: 0
From: .
Default

back to these ups's. so pressing the factory reset button is ok to do and doesnt affect any attached servers?
Reply
Old Aug 27, 2009 | 08:17 PM
  #13  
HHxx's Avatar
HHxx
Scooby Regular
 
Joined: Nov 2001
Posts: 2,576
Likes: 0
Default

On the management card, yes.
Reply
Old Aug 27, 2009 | 09:52 PM
  #14  
Davey P's Avatar
Davey P
Scooby Regular
iTrader: (1)
 
Joined: Aug 2002
Posts: 1,616
Likes: 0
From: Dorset
Default

On some of them you need to press it in once and then press it again within 8 seconds.
Reply
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
casasteve
Drivetrain
3
Sep 23, 2015 05:02 PM
Adam Kindness
ScoobyNet General
0
Sep 15, 2015 03:31 PM
PSI3
Drivetrain
9
May 3, 2002 07:02 AM
Sam Elassar
Scotland
29
Feb 28, 2002 12:08 AM
Paul Frank
ScoobyNet General
14
Jul 21, 2000 04:07 PM




All times are GMT +1. The time now is 05:01 AM.